Input Voltage: 90- 130VAC/180-240VAC
Power Range:12- 100W
High Efficiency: up to 89% ; PF>0.95
IP20 Design.
Cooling by free air convection
Suitable for dry or damp location use
Multiple protections like short circuit& over-current & over-voltage protection.
Compatible with Forward phase, Reverse phase, Triac, MLV, ELV Dimmers
5 years warranty
Model No. | Power | Output Voltage | Output Current | Weight | Size(L *W*Hmm) | Packing |
OTM-TD12W-12 OTM-TD12W-24 | 12W | 12V 24V | 1A 0.5A | 69g | 100*36* 18 | 325* 210* 385mm,180PCS/CTN |
OTM-TD20W-12 OTM-TD20W-24 | 20W | 12V 24V | 1.5A 0.83A | 69g | 100*36* 18 | 325* 210* 385mm,180PCS/CTN |
OTM-TD30W-12 OTM-TD30W-24 | 30w | 12V 24V | 2A 1.25A | 106g | 107*40*22 | 325' 210* 385mm,126PCS/CTN |
OTM-TD40W-12 OTM-TD40W-24 | 40w | 12V 24V | 3A 1.7A | 140g | 133* 47* 29 | 325* 210* 385mm,66PCS/CTN |
OTM-TD60W-12 OTM-TD60W-24 | 60W | 12V 24V | 4A 2.5A | 160g | 133* 47*29 | 325* 210 385mm,66PCS/CTN |
OTM-TD80W-12 OTM-TD80W-24 | 80W | 12V 24V | 5.5A 3.5A | 250g | 170*50*30 | 325* 210* 385mm, 50PCS/CTN |
OTM-TD100W-12 OTM-TD100W-24 | 100W | 12V 24V | 7A 4.2A | 370g | 190*65* 30 | 290* 230* 395mm,28PCS/CTN |
Specifications
Protection | Short Circuit | Intermittent restart mode, after the exception can be automatically restored |
Over Current | Hiccup mode, after the removal of abnormal flow can be automatically restored |
Environment | Working TEMP. | -30~+45°C |
Working Humidity | 5~95%RH |
Storage TEMP. Humidity | -40~+70*C,5~95%RH |
TEMP .cofficient | 士0.03%/°C (0~50°C) |
Vibration | 5- 55Hz/2g,30 Mimute |
Safety& EMC | Safety standards | EN60598 |
Withstand voltage | I/P-O/P:3KVAC IP-FG1.88VAC 0/P FG:0.5KVAC |
Isolation resistance | I/P-0/P I/P-FG 0/P-FG:100MΩ/500VDC/25*C/709RH |
EMC EMISSION | EN55022,EN55015 Class B |
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input , rated load and 25°Cof ambient tem perature. 2. To extend the drive's using life ,please reduce the loading at lower input voltage. |
Package
Dimensions
Driver Connecting Diagram
Dimming Operation
※The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection a triac dimmer.
※Usually matching with leading edge/Forward Phase Triac Dimmers( Can customized as a driver only matching trailing edge/reverse phase Triac Dimmers if needed).
※Please try to use dimmers with power at least 2.5 times as the output power of the driver.
※for Forward phase,Magnetic low voltage and Triac Dimmers
Warning
※Prevent to reverse polarity,
※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI;
※Risk of Fire. Istallation involves special wiring methods to run wiring through a building structure. Consult a qualified electrician;
※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.