Input Voltage:100-240Vac
Power Range:9W-80W
High Efficiency: up to 86%; PF>0.6
IP20 Design; Flicker-free
Cooling by free air convection
Suitable for dry or damp location use
Protection:Short Circuit/Over Loading/Over Current/ Over Temperature
3 years warranty
Model No. | Power | Output Voltage | Output Current | Weight | Size(L*W*Hmm) | Packing |
OTM-SS9 | 9W | 12V 24V | 0.5A 0.25A | 118g | 99*46*15 | 40*30*20CM,100PCS/CTN |
OTM-SS15 | 15W | 12V 24V | 1.25A 0.625A | 118g | 99*46*15 | 40*30*20CM,100PCS/CTN |
OTM-SS20 | 20W | 12V 24V | 1.67A 0.83A | 118g | 128*50*15 | 40*30*20CM,100PCS/CTN |
OTM-SS30 | 30W | 12V 24V | 2.5A 1.25A | 118g | 165*50*16.5 | 40*30*20CM,100PCS/CTN |
OTM-SS40 | 40w | 12V 24V | 3.33A 1.67A | 122g | 165*50*16.5 | 40*30*20CM,100PCS/CTN |
OTM-SS50 | 50w | 12V 24V | 4.17A 2.08A | 122g | 165*50*16.5 | 40*30*20CM,100PCS/CTN |
OTM-SS60 | 60W | 12V 24V | 5A 2.5A | 122g | 185*63.5*22 | 40*30*20CM,100PCS/CTN |
OTM-SS80 | 80W | 12V 24V | 6.67A 3.33A | 211g | 185*63.5*22 | 40*30*20CM,50PCS/CTN |
Specifications
Protection | Short Circuit | Hiccup mode, recover automatically after fault condition is removed |
Over Current | ≤1.2*| out | |
Over Loading | ≤120% | |
Over temperature | 100°C土10°C,Shut down o/p voltage, recover automatically after temperature goes down. | |
Environment | Working TEMP. | -40~+60°C |
Working Humidity | 20~90%RH, non-condensing | |
Storage TEMP. Humidity | -40~+80℃,10~95%RH | |
TEMP .cofficient | ±0.03%/℃(0~50℃) | |
Vibration | 10~500Hz,2G 12min./1 cycle,period for 72min. each along X,Y,Z axes | |
Safety& EMC | Safety standards | EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:3KVAC IP-FG:1.88KVAC O/P-FG:0.5KVAC | |
Isolation resistance | I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25℃/70%RH | |
EMC EMISSION | EN55022,EN55015 Class B | |
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input , rated load and 25°C of ambient temperature. 2. To extend the driver's using life ,please reduce the loading at lower input voltage |
Package
Dimensions
Driver Connecting Diagram
Warning
※Prevent to reverse polarity;
※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI;
※Risk of Fire. Installation involves special wiring methods to run wiring through a building structure. Consult a qualified electrician;
※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.