30W Triac/Phase Cut Dimmable 12V/24V Constant Voltage LED Driver High PF
VR&PWM output
Features:
·Output constant voltage
·UL cUL listed, Class 2, Class P, FCC, CE, RoHS, T24
·Universal input, 110-277Vac
·Build in active PFC, typical power factor>0.95, THD<10%@120V Max. load
·High efficiency: up to 80%
·Load: 0.01-100%
·Short-circuit, over-temperature, over-load protection
·Full protection metal case, for dry, damp locations Plastic enclosures can be used indoors
·Flicker-free
·Suitable for LED lighting and moving sign applications
Product advantage:
•Dim-all: Triac |
•Switch to PWM or Voltage Reduce output |
•Dimming effect: Voltage Reduce mode: 100%-0.01% dim, stepless dimming,flicker-free, PWM dim mode:100-0.1% dim, flicker-free |
•Triac dim mode: Forward phase & reverse phase, MLV, ELV dim |
•Flexible wiring compartment to adjust the AC and DC wiring space |
•Plastic housing NEMA 4X for indoor and outdoor use; Wet, damp, and dry location |
•Title 24 JA8 compliant |
•Constant voltage type, fine-tune of output voltage |
•Super low loading request, works perfectly at 0.01-100% load. |
7 years warranty |
Dimming range: 100%-0.01% Ultra Deep Amplitude |
No Vpeak-peak during driver on/off and dimming, no harm to the LED for long-term use, and slow down the speed of lumen depreciation. |
Works with single channel CCT warm-dim LED strip/tape (2 wires). |
Switching different output mode can be compatible with more different types of LED lamps |
compatible with DC-DC design LED fixtures, such as MR16, PAR, wall washer, linear lighting, LED strip/type |
Specification
Model | OTM-TD30-12 | OTM-TD30-24 | |||
Certificates | UL, cUL listed, Class 2 unit, Type HL rated, FCC | ||||
Output | DC Voltage | 12V | 24V | ||
Rated Current | 2.5A | 1.25A | |||
Rated Power | 30W | 30W | |||
Voltage Tolerance | ±0.5V | ||||
Voltage Regulation | ±0.5% | ||||
Load Regulation | ±1% | ||||
Input | Voltage Range | 110-277VAC | |||
Frequency Range | 47-63Hz | ||||
Power Factor(Typ.)@ full load | 0.99@120VAC 0.98@277VAC | 0.99@120VAC 0.95@277VAC | |||
THD(Typ.)@ full load | <20% | ||||
Efficiency(Typ.)@ full load | 79% @120Vac 80%@277Vac | 79% @120Vac 80%@277Vac | |||
AC Current(Max.) | 0.35A@100Vac | ||||
Inrush Current (Typ.) | 7A, 50%, 420us @120Vac 12A, 50%, 480us @277Vac | ||||
Leakage current | <0.50mA | ||||
Protection | Short Circuit | shut down o/p voltage, and re-power on to recover after the fault condition is removed | |||
Over Loading | ≤120% shut down o/p voltage, re-power on to recover after fault condition is removed | ||||
Over Temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||||
Environment | Working TEMP. | -40~+60℃ (see below derating curve) | |||
Working Humidity | 20~90%RH, non-condensing | ||||
Storage TEMP. Humidity | -40~+80℃,10~95%RH | ||||
TEMP .coefficient | ±0.03%/℃(0~50℃) | ||||
Vibration | 10~500Hz, 5G 10min./1 cycle, period for 60min. each along X, Y, Z axes | ||||
Safety& EMC | Safety standards | UL8750+UL1310 | |||
Withstand voltage | I/P-O/P:1.88KVAC | ||||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||||
EMC EMISSION | FCC Part 15 B | ||||
others | Net. Weight | 0.4Kg | |||
Size | 158*54*20*56*24mm (L*W*H) | ||||
packing | 40PCS/CTN SIZE:230*170*240mm(L*W*H) | ||||
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. 2. To extend the driver's use life, please reduce the loading at a lower input voltage. |
Derating Curve
To extend their life, please refer to the Derating Curve and derate according to the temperature.
To extend their life, please refer to the Derating Curve and derate according to the temperature
Mechanical Specification:
Unit:mm
Tolerance:0.5-2mm
Input with terminals Live(L) and Neutral(N) wires to be connected to AC
Output LED SEC output Positive (LED+), Output Negative (LED-). Connected to LED light
Dimming cable DIM (+) Purple to 0/1-10V dimmer signal(+ ),DIM (-) Pink to 0/1-10V dimmer signal (-)
Please make sure you connect these correctly otherwise your product will not function correctly and could be damaged.
Note: Any other requests we can customize.
Connecting Diagram
Using TRIAC/Phase cut dimming
1. The Pulse-Width Modulation (PWM) of the output voltage can be adjusted through the AC phase line(L) input terminal by connecting a phase /Triac dimmer of lighting system.
2. Work with forward phase /leading edge, MLV and reverse phase /trailing edge, ELV, and TRIAC dimmers.
3. Please try to use dimmers with power at least 1.5 times the output power of the driver.
The topology
PFC load graph
PWM dimming curve
VR dimming curve
Instruction:
1)This driver should be installed by qualified and professional person;
2)Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation.
3)Ensure that wiring is correct before test in order to avoid light and power supply damage;