Input Voltage: 100-240V
Power Range:18- 100W
High Eficiency: up to 83% ; PF>0.6
IP20 Design; Flicker-free
Cooling by free air convection
Suitable for dry or damp location use
Protection:Short Circuit/Over Loading/Over Current/ Over Temperature
3 years warranty
With 6-10 JST ports
Model No. | Power | Output Voltage | Output Current | Weight | Size(L*W*Hmm) | Packing |
OTM-SS18-CB | 18W | 12V 24V | 1.5A 0.75A | 91g | 118*52*18 | 40*30*20CM/CTN |
OTM-SS24-CB | 24W | 12V 24V | 2.00A 1.00A | 91g | 118*52*18 | 40*30*20CM/CTN |
OTM-SS30-CB | 30w | 12V 24V | 2.50A 1.25A | 91g | 118*52*18 | 40*30*20CM/CTN |
OTM-SS36-CB | 36w | 12V 24V | 3.00A 1.50A | 91g | 138*55*18 | 40*30*20CM/CTN |
OTM-SS50-CB | 50W | 12V 24V | 4.17A 2.08A | 91g | 138*55*18 | 40*30*20CM/CTN |
OTM-SS60-CB | 60W | 12V 24V | 5.00A 2.50A | 117g | 168*60*20 | 40*30*20CM/CTN |
OTM-SS75-CB | 75W | 12V 24V | 6.25A 3.13A | 207g | 198*60*20 | 40*30*20CM/CTN |
OTM-SS80-CB | 80W | 12V 24V | 6.66A 23.33A | 207g | 198*60*20 | 40*30*20CM/CTN |
OTM-SS100-CB | 100W | 12V 24V | 8.30A 4.16A | 207g | 198*60*20 | 40*30*20CM/CTN |
Specifications
Protection | Short Circuit | Hiccup mode, recover automatically after fault condition is removed |
Over Current | ≤1.2*I out | |
Over Loading | ≤120% | |
Over temperature | 100°C士10°C,Shut down o/p voltage,recover automatically after temperature goes down. | |
Environment | Working TEMP. | -40~+60°C |
Working Humidity | -40~+80°C,10~95%RH | |
Storage TEMP. Humidity | -40~+70*C,5~95%RH | |
TEMP .cofficient | 士0.039%/9C (0~50°C) | |
Vibration | 10~500Hz,2G 12min./1 cycle,period for 72min. each along X,Y,Z axes | |
Safety& EMC | Safety standards | EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:3KVAC IP. FG:1.88KVAC O/P-FG:0.5KVAC | |
Isolation resistance | I/P-0/P /P-FG O/P-FG:100MΩ/500VDC/25*C/70%RH | |
EMC EMISSION | EN55022, EN55015 Class B | |
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input , rated load and 25°C of ambient temperature. 2. To extend the driver's using life ,please reduce the loading at lower input voltage |
Package
Dimensions
Driver Connecting Diagram
Warning
※Prevent to reverse polarity;
※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI;
※Risk
of Fire. Istallation involves special wiring methods to run wiring
through a building structure. Consult a qualified electrician;
※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.