Features :
·Input Voltage: 90-130V/100-277V
·Power Range:30-100W
·High Efficiency: up to 89% ;
PF>0.95
·IP54
·Cooling by free air convection ·Suitable for dry or damp location use
·Protection:Short Circuit/Over Loading /Over Current/ Over Temperature
·5 years warranty
Model No. | Power | Output Voltage | Output Current | Weight(kg) | Size(L*W*Hmm) | Packing |
OTM-E30-12J OTM-E30-24J | 30W | 12V 24V | 2A 1.2A | 0.603 | 200*45*37 | 28PCS/CTN,28.6*22.5*39.5CM |
OTM-E40-12J OTM-E40-24J | 40W | 12V 24V | 3A 1.67A | 0.603 | 200*45*37 | 24PCS/CTN,28.6*22.5*39.5CM |
OTM-E60-12J OTM-E60-24J | 60W | 12V 24V | 4A 2.5A | 0.776 | 215*51*37 | 14PCS/CTN,28.6*22.5*39.5CM |
OTM-E80-12J OTM-E80-24J | 80W | 12V 24V | 5.5A 3.5A | 1.121 | 215*51*37 | 14PCS/CTN,28.6*22.5*39.5CM |
OTM-E100-12J OTM-E100-24J | 100W | 12V 24V | 8.33A 4.17A | 1.121 | 215*51*37 | 14PCS/CTN,28.6*22.5*39.5CM |
Specifications
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition is removed |
Over Current | ≤1.2*Iout | |
Over Loading | ≦120% shut down o/p voltage, re-power on to recover | |
Over temperature | 100℃± 10℃ shut down o/p voltage ,re-power on to recover | |
Environment | Working TEMP. | -40~+70℃ |
Working Humidity | 20~90%RH, non-condensin | |
Storage TEMP. Humidity | -40~+80℃,10~95%R | |
TEMP .cofficient | 士0.03%/℃(0~50℃) | |
Vibration | 10~500Hz,2G 10min./1 cycle,period for 72min. each along X,Y,Z axes | |
Safety& EMC | Safety standards | UL8750+UL1310 Class 2 unit , EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:3.75KVAC | |
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%R | |
EMC EMISSION | EN55015,EN61000-3-2,3 (≧60%loading),FCC Part 15 B | |
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃ of ambient temperature 2. Tolerance: includes set us tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again 4. Loading range from 10% to 100 |
Package
Dimensions
Driver Connecting Diagram
Dimming Operation
※Connect the Dali signal line to the Dali bus of the controller (the Dali Master). After Dali Master scanning and address assignment, the driver can be successfully dimmed. Please refer to Diagram 1 ※Notice:In the market, some DALI controllers has bus-powered functions .If not,please add an extra power supply. (DALI Power)
※Any incorrect connecting of signal line and output line would damage the master.
Warning
※This driver should be installed by qualified and professional person;
※Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation.
※Ensure that wiring is correct before test in order to avoid light and power supply damage;
※If driver Cannot work normally, don’t maintain privately; Have any question, please contact us.