• 96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    96W IP67 Triac Dimmable Constant Voltage Linear LED Driver
    ❤ Add to collection
  • 96W IP67 Triac Dimmable Constant Voltage Linear LED Driver

    110-277Vac
    0.01-100%
    10-100%
    Triac Dim.
    constant voltage
    IP67
    7 years
    ROHS,UL,FCC,Class 2,Class P,SELV

    96w 12V 24V Waterproof IP67 Linear Triac Dimmable LED Driver 
    Spec Sheet Download



    • U.S.$0.00
      U.S.$0.00
      U.S.$0.00
      U.S.$0.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.000KG
    • Quantity:
Description

96w 12V 24V Waterproof IP67 Linear Triac Dimmable LED Driver 
Spec Sheet Download





·Output constant voltage/VR or PWM output set selection

·Range: 110-277VAC    

·Built-in active PFC function Power Factor: up to 0.95

·Efficiency up to 89% 

·Dimming: 100-0.1% at PWM output,100%-0.01% dim at VR output,

·Load: 10-100% at PWM output, 0.01-100% at VR output

·Protection:short circuit/over loading/ Over temperature

·Full protection Aluminum shell, IP67 for indoor and outdoor installation

·Flicker-free

·Dimming function:

·Phase dimming: work with leading edge and trailing edge TRIAC dimmers 

·Cooling by free air convection                             

·Suitable for LED lighting and moving sign applications   


Model

OTM-TD96-SW24

OTM-TD96-SW48

Output

DC Voltage

24V

48V

Voltage Tolerance

±0.5V

Voltage Regulation

±0.5%

Rated current

4A

2A

Rated power

96W

Load Regulation

±2%

Input

Voltage Range

110-277VAC 

Frequency Range

47 - 63Hz

Power Factor(Typ.)@ full load

PF≥0.95/230VAC

THD(Typ. ) @ full load

<20%

Efficiency(Typ.)@ full load

87%@120VAC    89% @277VAC.

87%@120VAC    89% @277VAC.

AC Current(Max.)

1.04A@110VAC

Inrush Current (Typ.)

47.5A/312uS@50%Ipeak 230VAC

Leakage current

<0.5mA 

Protection

Short Circuit

shut down o/p voltage, re-power on to recover after fault condition removed

Over Load

≤120% shut down o/p voltage, re-power on to recover after fault condition is removed

Over temperature

100℃±10℃

Protection Class

IP67

Environment

Working TEMP.

-40~+60℃ (see below derating curve)

Working Humidity

20 - 90%RH,non-condensing 

Storage TEM.,Humidity

-40 - +80℃,10 - 95%RH

TEMP.coefficient

±0.03%/℃(0 - 50℃)

Vibration

10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes 

Safety & EMC

Safety standards

UL8750+UL1310 

Withstand voltage

I/P-O/P:3.75KVAC  I/P-FG:1.88KVAC  O/P-FG:0.5KVAC 

Isolation resistance

I/P-O/P I/P-FG O/P-FG: 100MΩ/500VDC/25℃/70%RH  

EMC Emission

FCC Part 15 B

Others

Net Weight

0.55Kg  

Dimension

330*33*24mm(L*W*H)

packing

30pcs /CTN SIZE: 360X270X175mm

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature.

2. Tolerance: includes set up tolerance, line regulation and load regulation .

3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again.


UsingTriac MLV wiring diagram



Size Drawing:




※ Input : Cable H05RN-F 3*1.0mm² Black(L)and White(N) to connect to L and N of Mains AC;the green /yellow cable connect with (FG),

※Output : Cable H05RN-F 2*1.0mm²  "Red" (+) to  LED Positive side (+) , "Black"(-)  to LED Negative side (-).

 ※Please make sure your connect these correctly otherwise your product will not function correctly and could be damaged.

※Note: Any other requests we can customized.  


Warning

※Prevent to reverse polarity;

※Risk of Electric Shock. When used outdoors, install only on a circuit protected by a Class A GFCI;

※Risk of Fire. Istallation involves special wiring methods to run wiring through a building structure. Consult a qualified electrician;

※Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
Dimmable LED Driver
5 in 1 Dimmable
Triac Dimmable
3 in 1 Dimmable
Dali Dimmable
0/1-10V Dimmable
DALI+PUSH Dimmable
Non Dimmable LED Driver
IP 20
IP 67
Submit product