Constant Voltage JUNCTION Box LEDdriver 96W
·Output constant voltage
·UL cUL listed, Class 2, Class P, Type HL, FCC, NEMA 4X, T24
·Universal input, 110-277Vac
·Build in active PFC, typical power factor>0.95
·THD<20%@120V Max. load
·High efficiency : up to 87%
·Short-circuit, over-temperature, over-load protection
·Full protection metal case, for dry, damp, wet location
·Flicker-free
·Suitable for LED lighting and moving sign applications
Specifications
Model | OTM-JB96-12 | OTM-JB96-24 | |
Certificates | UL, cUL listed, Class 2 unit, Type HL rated, FCC NEMA 4X, T24 | ||
Output | DC Voltage | 24V | 48V |
Rated Current | 4A | 2A | |
Rated Power | 96W | 96W | |
Voltage Tolerance | ±0.5V | ||
Voltage Regulation | ±0.5% | ||
Load Regulation | ±1% | ||
Input | Voltage Range | 110-277VAC | |
Frequency Range | 47-63Hz | ||
Power Factor(Typ.)@ full load | 0.98@120VAC 0.97@277VAC | ||
THD(Typ.)@ full load | <20% @120VAC &277VAC | ||
Efficiency(Typ.)@ full load | 12V/24V 86% @120Vac 88%@277Vac 36V/48V 88%@120Vac 89%@277Vac | ||
AC Current(Max.) | 1.3A@110Vac | ||
Inrush Current (Typ.) | 20A, 50%, 1.6ms @120VAC; 25A, 50% 1.2ms @277VAC | ||
Leakage current | <0.50mA | ||
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition is removed | |
Over Loading | ≤120% Hiccup mode,recovers automatically after fault condition is removed | ||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
Environment | Working TEMP | -40~+60℃ (see below derating curve) | |
Working Humidity | 20~90%RH, non-condensing | ||
Storage TEMP. Humidity | -40~+80℃,10~95%RH | ||
TEMP .coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||
Safety& EMC | Safety standards | UL8750+UL1310 | |
Withstand voltage | I/P-O/P:1.88KVAC | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | FCC Part 15 B | ||
others | Net. Weight | 1.1Kg | |
Size | 226.5*117.5*42.5mm (L*W*H) | ||
packing | 10PCS/CTN | ||
Notes |
|
■ Derating Curve
To extend their life, please refer to the Derating Curve and derate according to the temperature.
■ Mechanical Specification
※ Input wire Black and White to be connected to AC L and N ,Green wire go ground,
※Output wire Red to LED Positive side (+) , Black to LED Negative side (-).
※Please make sure your connect these correctly otherwise your product will not function correctly and could be damaged.
※Note: Any other requests we can customized.
■ Connecting Diagram(1)
■ Connecting Diagram(2)
■ Instruction:
1) This driver should be installed by qualified and professional person;
2) Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation;
3) Ensure that wiring is correct before test in order to avoid light and power supply damage;