IP20 Round shape 30W 0-10V dimmable constant voltage led driver
Input Voltage: 90-130V/180-240V/100-240V
Power Range:12-80W
High Efficiency: up to 89% ; PF>0.95
IP20 Design
Cooling by free air convection
Suitable for dry or damp location use
Multiple protections like short circuit& over-current & over-voltage
Compatible with 0/1-10V Dimmers
5 years warranty
Model No. | Power | Output Voltage | Output Current | Weight | Size(L*W*Hmm) | Packing |
OTM-PDR12-12 OTM-PDR12-24 | 12W | 12V 24V | 1A 0.5A | 50g | D67*21 | 29* 23*39.5CM,90PCS/CTN |
OTM-PDR20-12 OTM-PDR20-24 | 20W | 12V 24V | 1.5A 0.83A | 70g | D67*21 | 29* 23*39.5CM,90PCS/CTN |
OTM-PDR30-12 OTM-PDR30-24 | 30w | 12V 24V | 2A 1.25A | 100g | D73*27 | 32.5*21*38.5CM,68PCS/CTN |
OTM-PDR40-12 OTM-PDR40-24 | 40w | 12V 24V | 3A 1.7A | 145g | D79*31 | 29* 23*39.5CM,36PCS/CTN |
OTM-PDR60-12 OTM-PDR60-24 | 60W | 12V 24V | 4A 2.5A | 220g | D102*31 | 32.5*21*38.5CM,36PCS/CTN |
OTM-PDR80-12 OTM-PDR80-24 | 80W | 12V 24V | 5.5A 3.5A | 220g | D102*31 | 32.5*21*38.5CM,36PCS/CTN |
Specifications
Protection | Short Circuit | Intermittent restart mode, ater the exception can be automatially restored |
Over Current | Hiccup mode, after the remowal of abnormal flow can be automatically restored |
Environment | Working TEMP. | -30~+45*C |
Working Humidity | 5~95%RH |
Storage TEMP. Humidity | -40~+70*C,5~95%RH |
TEMP .cofficient | 士0.03%/°C (0~50°C) |
Vibration | 5-55Hz/2g.30 Mimute |
Safety& EMC | Safety standards | EN60598 |
Withstand voltage | I/P- 0/P:3KVAC IP FG1.88KVAC 0/P.FG0.5KVAC |
Isolation resistance | I/P-0/P I/P FG 0/P F:100MΩ/500VDC/25C/70%RH |
EMC EMISSION | EN55022, EN55015 Class B |
Notes | 1. All parameters if NOT specially mentioned are measured at 120VAC input, rated load and 25°Cof ambient tem perature. 2. To extend the drive's using life ,please reduce the loading at lower input voltage. |
Package
Dimensions
Driver Connecting Diagram
Dimming Operation
※Built-in 0-10V,1-10V dimming function .Output luminous can be adjusted through output cable by connecting a resistance or 0/1-10Vdc signal between DIM+ and DIM-.
※Please DO NOT connect “DIM-”to “LED-”
Warning
※This driver should be installed by qualified and professional person;
※Please make sure the driver is installed with adequate ventilation around it to allow for heat dissipation.
※Ensure that wiring is correct before test in order to avoid light and power supply damage;
※If driver Cannot work normally, don’t maintain privately; Have any question, please contact us.