Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition removed |
Over Loading | 30W: ≤120% shut down o/p voltage, re-power on to recover after fault condition removed 60W/300W: ≤120% Hiccup mode,recovers automatically after fault condition is removed 80W-120W: ≤120% constant current limiting, auto-recovery |
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. |
Environment | Working TEMP. | -40~+60℃ |
Working Humidity | 20 - 95%RH,non-condensing |
Storage TEMP. Humidity | -40~+80℃,10~95%RH |
TEMP .cofficient | ±0.03%/℃(0~50℃) |
Vibration | 30W-60W: 10~500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes 80W-300W: 10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes |
Safety& EMC | Safety standards | UL8750 +UL1310,CAN/CSA-C22.2 No.250.13 EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:1.88KVac |
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH |
EMC EMISSION | FCC 47 CFR Part 15 Subpart B, EN55015,EN61000-3-2,3 (≧60%loading) |
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input , rated load and 25℃ of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3.
The power supply is considered as a component that will be operated in
combination with final Equipment. Since EMC performance will be affected
by the complete installation, the final equipment manufactures must
be-qualify EMC Directive on the complete installation again. |