Features : ·Input Voltage: 90-130V/180-240V/100-240V ·
Power Range:12-100W
·High Efficiency: up to 89% ;PF>0.9
·IP67 Design
·Cooling by free air convection ·Suitable for dry or damp location use
·Multiple protections like short circuit& overcurrent & over-voltage protection.
·Compatible with DALI Dimmers
·5 years warranty
Model No. | Power | Output Voltage | Output Current | Weight(g) | Size(L*W*Hmm) | Packing |
OTM-DD12-W12 OTM-DD12-W24 | 12W
| 12v 24v | 1A 0.5A | 212g | 115*38*22 | 29*23*40CM |
OTM-DD20-W12 OTM-DD20-W24
| 24W | 12v 24v | 1.5A 0.83A | 248g | 115*38*22 | 29*23*40CM |
OTM-DD30-W12 OTM-DD30-W24 | 30W
| 12v 24v | 2A 1.25A | 472g | 125*42*28 | 29*23*40CM |
OTM-DD40-W12 OTM-DD40-W24 | 40W
| 12v 24v | 3A 1.7A | 95 | 120*55*18 | 29*23*40CM |
OTM-DD60-W12 OTM-DD60-W24 | 60W | 12v 24v | 4A 2.5A | 608g | 155*42*28 | 29*23*40CM |
OTM-DD60-W12 OTM-DD60-W24 | 60W | 12v 24v | 4A 2.5A | 608g | 155*42*28 | 29*23*40CM |
OTM-DD80-W12 OTM-DD80-W24 | 80W | 12v 24v | 5.5A 3.5A | 616g | 180*42*28 | 29*23*40CM |
OTM-DD100-W12 OTM-DD100-W24 | 100W | 12v 24v | 7A 4.2A | 616g | 180*50*40 | 29*23*40CM |
Specifications
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition is removed |
Over Current | ≤1.2*I out |
Over Loading | ≦120% shut down o/p voltage, re-power on to recover |
Over temperature | 100℃± 10℃ shut down o/p voltage ,re-power on to recover |
Environment | Working TEMP. | -40~+70℃ |
Working Humidity | 20~90%RH, non-condensing |
Storage TEMP. Humidity | --40~+80℃,10~95%RH |
TEMP .coefficient | ±0.03%/℃(0~50℃) |
Vibration | 10~500Hz,2G 10min./1 cycle,period for 72min. each along X,Y,Z axes |
Safety& EMC | Safety standards | UL8750+UL1310 Class 2 unit , EN61347-1 EN61347-2-13 |
Withstand voltage | I/P-O/P:3.75KVAC |
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH |
EMC EMISSION | EN55015,EN61000-3-2,3 (≧60%loading),FCC Part 15 B |
Notes |
All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃ of ambient temperature. Tolerance: includes set us tolerance, line regulation and load regulation . The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again Loading range from 10% to 100%
|
Package
Dimensions
Driver Connecting Diagram